Electronic-Pole-Reversal-Control-Unit 757
The Electronic-Pole-Reversal-Control-Unit 757 is a controllable current or voltage source for magnetising and reversing the polarity of electromagnets
It is operated via 24 V DC control inputs. The system statuses are displayed via 4 LEDs.
A polarity reversal process is required to reduce the residual magnetism when switching off electromagnets. This generates a magnetic field that changes polarity and decreases in intensity. This process ensures that the residual magnetism is reduced to a minimum. The USG 757 regulates the necessary currents / voltages through the magnet. A basic factory setting of the electrical nominal values is carried out when the USG 757 is delivered. If required, the polarity reversal process can be changed by selecting a different polarity reversal programme. It is also possible to change the polarity reversal programmes and the holding force levels individually using the optionally available monitor programme.
It is operated via 24 V DC control inputs. The system statuses are displayed via 4 LEDs.
A polarity reversal process is required to reduce the residual magnetism when switching off electromagnets. This generates a magnetic field that changes polarity and decreases in intensity. This process ensures that the residual magnetism is reduced to a minimum. The USG 757 regulates the necessary currents / voltages through the magnet. A basic factory setting of the electrical nominal values is carried out when the USG 757 is delivered. If required, the polarity reversal process can be changed by selecting a different polarity reversal programme. It is also possible to change the polarity reversal programmes and the holding force levels individually using the optionally available monitor programme.
With the optional multi-magnet mode, up to four data sets of different magnets can be saved. The data records contain all the data relevant for solenoid control. This means that up to four different solenoids can be operated alternately on one pole-reversal control unit.
ACCESSORIES:
Power supply units for the DC supply:
For the DC supply of the USG 757, we offer suitable switching power supply units for single-phase and three-phase mains connection in various power sizes
Control unit
We offer various type 744 control units for manual control of the pole-changing control unit. These are equipped with a coding switch for setting the holding force and with illuminated buttons for energising and reversing the polarity of the solenoid. buttons and coding switches are also available as built-in parts.
For the DC supply of the USG 757, we offer suitable switching power supply units for single-phase and three-phase mains connection in various power sizes
Control unit
We offer various type 744 control units for manual control of the pole-changing control unit. These are equipped with a coding switch for setting the holding force and with illuminated buttons for energising and reversing the polarity of the solenoid. buttons and coding switches are also available as built-in parts.
Monitor programme
The additional "USG Monitor" software significantly expands the configuration options for the pole-reversal control unit.
The following options are available:
The additional "USG Monitor" software significantly expands the configuration options for the pole-reversal control unit.
The following options are available:
- Selection of the 6-, 8- and 16-stage adhesive force curve or individual modification of the individual adhesive force stages
- Changing the pole reversal programmes
- Activation of special options
Control units - Features
Control units - Features | |
---|---|
Einsatzgebiete | Holding and Transport, Clamping |
Nominal voltage range | 24 [V DC] |
max. rated current | up to 16 [A] |
Magnet design | Electro-magnet |
Ausführungsoptionen | Adjustment of Clamping Force, Electrical Cabinet |
Protection class | IP 20 |
Downloads
Detailierte Angaben zu den Control units - Features finden Sie in den Datenblättern.Um den Download zu starten, wählen Sie bitte eine Datei aus. Monitor programme pole-changing control unit 756/757Electronic pole-reversal control unit 757
The Highlights
SERIES 757
- Developed for applications for generating safety extra-low voltage (SELV) or functional extra-low voltage (PELV)
- High output currents up to 16 A for electromagnets, with an extremely compact design
- Very short switching times
- Optional current-regulated or voltage-regulated operation
- Preselection of up to 4 freely programmable solenoid parameter sets via optional control inputs
- Very fine resolution of the holding force levels
- the digital outputs can switch currents of up to 1.5 A in total
- Due to its small design, the device is suitable for mounting on a standard mounting rail in a control cabinet in a vertical arrangement
- Configuration via USB with monitor programme (optional)
Technical data
SERIES 757
DESCRIPTION | VALUE |
Connection: | a suitable (SELV/PELV) AC / DC power supply unit (e.g. Puls CPS20.481 or CP10.481 power supply unit) |
Directives: | EMC and Low Voltage Directive |
Input voltage: | 26 V DC to 56 V DC |
Output voltage: | Up to 50 V DC (depending on the input voltage) |
Output current: | Electro solenoids max. 16 A Electropermanent solenoids max. 25 A (16 A per line) |
Efficiency: | Approx. 98 % |
Short-circuit behaviour: | Has an overcurrent cut-out and is short-circuit protected |
Signal inputs: | 12 inputs 24 V DC 2 mA per input |
Signal outputs: | 5 outputs High side switch 24 V, max. 1.5 A (in total for all 5 outputs) |
Internal supply: | 24 V, max. 1.5 A |
Polarity reversal programmes: | 16, freely programmable |
Holding force curves: | Up to 256 levels (16 freely programmable, interpolated in between) |
Interface: USB | USB |
Protection class: | IP 20 (switch cabinet installation) |
Dimensions (WxHxD): | 22.5 mm x 126 mm x 102.5 mm |
Weight | 160 g |
Ambient temperature: | Permissible in operation 0 °C to 40 °C Permissible during storage and transport -20 °C to 70 °C |
Air humidity: | max. 90 %, condensation not permitted |
Power loss: | max. 10 W |
Max. installation altitude: | 1000 m above sea level (operation at higher altitudes reduces the possible output power) |
Wagner
Pluspoints
At a glance
- Maintenance-free
- Robust design and service-friendly
connection terminals - Short-circuit proof
- Customer-specific customisation (holding force levels / optimisation of polarity reversal programs) possible via monitor program