Plate-Demagnetizing-Unit 211 / 15
Ferromagnetic parts are very often magnetised by transport magnets or by machining on magnetic clamping systems. These parts can be demagnetised with the plate demagnetising devices.
During the demagnetisation process, the workpieces are guided across the pole gap at a speed of approx. 0.06 to 0.12 m/s. It must be ensured that the workpiece is guided approx. 30 cm before and after the demagnetising device at the same speed. This process can be repeated for large parts in order to achieve a better demagnetisation result.
A plastic plate applied to the pole surface protects finished workpieces from damage. Bulk parts can also be demagnetised in a flat container made of non-magnetic material. However, in order to achieve an optimum demagnetisation result here too, the parts must not touch each other.
The duty cycle of the devices is 100%, making them suitable for retrofitting in automated systems. They can be installed upright or suspended.
In the case of high-alloy, tempered workpieces or components with complicated shapes, the demagnetisation quality can be further improved by connecting a Wagner type 244 low-frequency generator upstream.
Demagnetising properties
Demagnetising properties | |
---|---|
Effective depth/height up to | 30 [mm] |
max. component width | 500 [mm] |
Single/quantities | Individual components |
Power amplification | no |
Ausführungsoptionen | Tandem-Design - Hydraulical Height-Adjustment of upper Demagnetizer, Tandem-Design - Mechanical Height-Adjustment of upper Demagnetizer, Tandem-Design with Low-Frequency-Generator, Standard Table Design |
Downloads
Detailierte Angaben zu den Demagnetising properties finden Sie in den Datenblättern.Um den Download zu starten, wählen Sie bitte eine Datei aus. Platten-Entmagnetisier-Gerät 211-15/17/28/40
The Highlights
SERIES 211-15
- High energy efficiency
- Minimal installation space thanks to compact design
- Variable mounting and installation options
- Easy to use at any power socket
- Can be used as a table-top device in the workshop as well as for integration into fully automated process chains
- Minimised residual radiation due to magnetic field concentration on the pole surface
- Designed for continuous operation, 100% ED
- Covers the vast majority of applications thanks to modular assembly concept Type 211
- Operation with mains frequency or low frequency (with ballast 244)
Technical data
SERIES 211-15
Type |
Width
a [mm]
|
Demagnetising area b [mm]
|
Overall height
c [mm]
|
Overall length (EA only)
d [mm]
|
Power [V/A] | Protection class | Weight [kg] |
211-15/16 | 148 | 160 | 121 | 278 | 850 | IP 54 | 22 |
211-15/16 S-1 | 148 | 160 | 121 | 237 | 850 | IP 65 | 21 |
211-15/25 | 148 | 250 | 121 | 368 | 1380 | IP 54 | 30 |
211-15/25 S-1 | 148 | 250 | 121 | 327 | 1380 | IP 65 | 30 |
211-15/40 | 148 | 400 | 121 | 518 | 2050 | IP 54 | 46 |
211-15/40 S-1 | 148 | 400 | 121 | 477 | 2050 | IP 65 | 46 |
211-15/50 S-1 | 148 | 500 | 121 | 577 | 2200 | IP 65 | 57 |
Wagner
Pluspoints
At a glance
- Customised design
- AfterSalesService WAGNER-Plus
- Sustainability - Energy-efficient
- Maintenance-free design
- Assembly concept
- LongLife Repair PLUS
- Extreme robustness - design and connections
- IP versions - min. IP 54
- Replaceable wear plate
- Test set-up can be booked at the WAGNER TECHNIKUM